Multi-Voltage Conventional Relays System Sensor's multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features * Multi-voltage operation * Activation LEDs * Easy and flexible installation * Reliable and robust design * Multipurpose field installations * Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-10T/20T and R-14T/24T * Removable front cover on steel enclosure for R-10E/R-20E and R14/R-24E, which mount inside the enclosure * LED viewing hole on top of the steel enclosure's cover * Extra pair of wires for redundant power input on PR-3 * Terminal strip field wiring connections, mounting track, and hardware The R-10T, R-20T, R-14T, and the R-24T models are multivoltage relays with terminal strip field wiring connections, mounting track, and hardware. The R-10T is a single FORM-C (SPDT) relay with a red activation LED, and the R-14T is a four-gang 1 FORM-C (SPDT) relay with four red activation LEDs. The R-20T is a single 2 FORM-C (DPDT) relay with a red activation LED, and the R-24T is a four-gang 2 FORM-C (DPDT) relay with four red activation LEDs. The R-10E/R-20E and R-14E/R-24E are similar to the T-series track mount relays, but they are mounted into a steel enclosure. The enclosure has a removable front cover that provides easy access and an LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epoxy encapsulated multi-voltage relays. They are single-pole double-throw relays that use a red LED as a visible indication of relay coil energization. PR-3 is identical to PR-2, except it has an extra pair of wires for redundant power input. Model EOLR-1 is an epoxy encapsulated, single-pole single-throw, normally open relay that can be used as an end of line device in fire alarm systems, e.g. to supervise power supplies. Agency Listings Multi-Voltage Conventional Relay Specifications Specifications: R-10T/R-14T/R-20T/R-24T Operating Voltage 18 - 35 VDC, 18 - 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10T/R-14T) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20T/R-24T) Operating Temperature -40F to 158F (-40C to 70C) Humidity Range 10% - 93% non-condensing Dimensions R-10T/R-20T: 2.5L x 3.35W x 1.2H R-14T/R-24T: 10L x 3.35W x 1.2H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: R-10E/R-14E/ R-20E/R-24E Operating Voltage 18 - 35 VDC, 18 - 35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10E/R-14E) 40 mA DC max. @ 24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20E/R-24E) Operating Temperature -40F to 158F (-40C to 70C) Humidity Range 10% - 93% non-condensing Dimensions R-10E/R-20E: 5.1L x 3.75W x 2.5H R-14E/R-24E: 11L x 5.3W x 2.5H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10 A 120 VAC: 1/6 HP 230 VAC: 7 A Specifications: PR-1 Operating Voltage Operating Current Operating Temperature Humidity Range Wire Length Dimensions Contact Ratings 18 - 35 VDC, 18 - 35 VAC, 120 VAC 15 mA DC max. @ 24 VDC, 24 VAC, 120 VAC -40F to 158F (-40C to 70C) 10 - 93% RH 8 minimum 0.87H x 2.01W x 1.42D 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive 10 to 40 VDC 30 mA DC max. -40F to 158F (-40C to 70C) 10 - 93% RH 8 minimum 0.91H x 1.65W x 1.22D 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) 9 to 40 VDC 20 mA DC max. -22F to 140F (-30C to 60C) 10 - 93% RH 8 minimum 120 VAC: 0.5 A max. (resistive load) 30 VDC: 3 A max. (resistive load) Specifications: PR-2/PR-3 Operating Voltage Operating Current Operating Temperature Humidity Range Wire Length Dimensions Contact Ratings Specifications: EOLR-1 Operating Voltage Operating Current Operating Temperature Humidity Range Wire Length Contact Ratings PR-1 E0LR-1 PR-3 R-10E & R-20E Enclosure PR-2 R-10T R-14T R-14E & R-24E Enclosure 3825 Ohio Avenue * St. Charles, IL 60174 Phone: 800-SENSOR2 * Fax: 630-377-6495 (c)2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0372-005 * 3/07 * #1782 |
Price & Availability of EOLR-1 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |